Screen Label Description Type Typical Range Units
      Min Max  
SW1 State of the external switch 1. Boolean  OFF ON  
SW2 State of the external switch 1. Boolean  OFF ON  
SW3 State of the external switch 1. Boolean  OFF ON  
SW4 State of the external switch 1. Boolean  OFF ON  
SW5 State of the external switch 1. Boolean  OFF ON  
SW6 State of the external switch 1. Boolean  OFF ON  
FET1 State of driver FET switch 1 Boolean  OFF ON  
FET2 State of driver FET switch2 Boolean  OFF ON  
FETINH State of driver FET inhibit signal Boolean  OFF ON  
SNS VOLT Voltage on the differential sensor (usually throttle position or pressure sensor), depending on the application. Voltage 0 5 Volts
BUS VOLT 12 V power supplied to the controller. Voltage 8 15 Volts
FET CRNT Measured current in amps supplied to the FET switches. Current 0 to 5 5 Amps
SW1 PLUP State of the programmable pullup current source on external switch 1. Boolean  OFF ON  
SW2 PLUP State of the programmable pullup current source on external switch 2. Boolean  OFF ON  
SW3 PLUP State of the programmable pullup current source on external switch 3. Boolean  OFF ON  
SNS GND Enable / disable for the grounding switch on the differential sensor. Boolean  OFF ON  
FREQ IN0 Measured frequency on the speed / tachometer input 0. Frequency 0 6000 Hz
FREQ IN1 Measured frequency on the speed / tachometer input 1. Frequency 0 6000 Hz
FREQ OUT1 Output frequency of the programmable tachometer / speed output. Frequency 0 6000 Hz
ENG. RPM Measured engine speed in RPM. Rotational Speed 0 15000 RPM
TOSS RPM Measured transmission output shaft or speedometer cable speed. Rotational Speed 0 10000 RPM
SPEED Vehicle speed in MPH. Speed 0 200 MPH
TPS Throttle position in percentage. Percentage 0 100 %
CLOCK Running time clock. Time 0   seconds
LK TPS Throttle position above which the torque converter clutch is always unlocked. Percentage 0 100 %
ULK TPS Throttle position below which the torque converter clutch is always unlocked. Must be less than LK TPS. Percentage 0 100 %
LK SPD Minimum speed at which the torque converter clutch may be locked. Speed 30 100 MPH
ULK SPD Speed below which the torque converter clutch is always unlocked. Must be less than LK SPD. Speed 30 100 MPH
LK DLY Time, in seconds, after 4th gear engagement, to allow torque converter clutch actuation. Time 0 2.5 seconds
TPS VOLT Voltage on the throttle position sensor. Voltage 0 5 Volts
TPS LOW Voltage on the throttle position sensor that corresponds to 0% throttle Voltage 0 4.5 Volts
TPS HIGH Voltage on the throttle position sensor that corresponds to 100% throttle Voltage 0.5 5 Volts
PRESSURE Measured pressure in PSI when a pressure sensor is connected to the differential sensor input. Pressure 0 300 PSI
OD MIN Overdrive engagement speed at closed throttle (0%) Speed 30 100 MPH
OD WOT Overdrive engagement speed at wide open throttle (100%). Speed 30 100 MPH