OPTIONS Connector
|
A |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
B |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
Note: This is the view into the receptacle on controller, not the plug.
|
CONNECTOR |
ROW |
PIN |
NAME |
FUNCTION |
WIRE COLOR |
TERMINATION |
NOTES |
|---|---|---|---|---|---|---|---|
|
OPTIONS |
A |
1 |
12 V |
12 VOLT OUT |
|
|
|
|
OPTIONS |
A |
2 |
5 V |
5 VOLT DISPLAY |
YELLOW |
DISPLAY PLUG |
|
|
OPTIONS |
A |
3 |
CAN2+ |
CAN BUS 2 HIGH SIGNAL |
|
|
|
|
OPTIONS |
A |
4 |
RS232 TX |
DISPLAY |
RED |
DISPLAY PLUG |
|
|
OPTIONS |
A |
5 |
LIN DATA |
COMMUNICATION |
|
|
|
|
OPTIONS |
A |
6 |
NO CONNECTION |
|
|
|
|
|
OPTIONS |
A |
7 |
NO CONNECTION |
|
|
|
|
|
OPTIONS |
A |
8 |
NO CONNECTION |
|
|
|
|
|
OPTIONS |
A |
9 |
SOLENOID 12 |
REVERSE LAMP RELAY |
|
|
Must drive relay, not lamps directly. |
|
OPTIONS |
A |
10 |
SOLENOID 11 |
NEUTRAL START RELAY |
|
|
Not available on GM 4L80E, GM 4L60E, GM 4L65E |
|
OPTIONS |
A |
11 |
SOLENOID 10 |
|
|
|
|
|
OPTIONS |
A |
12 |
SOLENOID 9 |
|
|
|
|
|
OPTIONS |
B |
1 |
GND |
GND |
|
|
|
|
OPTIONS |
B |
2 |
GND |
GND DISPLAY |
BLACK |
DISPLAY PLUG |
|
|
OPTIONS |
B |
3 |
CAN2- |
CAN BUS 2 LOW SIGNAL |
|
|
|
|
OPTIONS |
B |
4 |
RS232 RX |
DISPLAY |
GREEN |
DISPLAY PLUG |
|
|
OPTIONS |
B |
5 |
CALIBRATION SELECT 1 |
|
|
|
|
|
OPTIONS |
B |
6 |
CALIBRATION INDICATOR 1 |
|
|
|
|
|
OPTIONS |
B |
7 |
CALIBRATION SELECT 2 |
|
|
|
|
|
OPTIONS |
B |
8 |
CALIBRATION INDICATOR 2 |
|
|
|
|
|
OPTIONS |
B |
9 |
TCC MANUAL ENGAGE |
TURNS ON TCC |
BLU/OR |
TO SWITCH |
SWITCH TO GND |
|
OPTIONS |
B |
10 |
TCC LOCKUP INDICATOR |
POWERS LED |
BLU |
TO LED |
|
|
OPTIONS |
B |
11 |
NO CONNECTION |
|
|
|
|
|
OPTIONS |
B |
12 |
NO CONNECTION |
|
|
|
|